US Solutions USG STRUCTURAL PANEL CONCRETE ROOF DECK - Usg.com
USG STRUCTURAL PANEL CONCRETE ROOF DECK See recommended fasteners within this submittal sheet. USG Structural Panel Concrete Roof Decks can carry a total load, live and dead, of 150 psf (7.2 kPa) on cold-formed steel framing is spaced 48 in. (1220mm) o.c. ... Fetch This Document
Prolong The Life Of Your Steep Slope roof With Proper ...
Slope roof with proper ventilation by using Hunter Panels Cool-Vent. Hunter Panels Cool-Vent can be used with a variety of finished roof assemblies including all types and weights of Shingles, Slate, Tile and Metal Roof Deck Fasteners TAKE THE HUNTER ADVANTAGE ... Read Content
ARCHITECTURAL SPECIFICATIONS FULLY ADHERED SYSTEM
ARCHITECTURAL SPECIFICATIONS FULLY ADHERED SYSTEM A1.00 GENERAL A1.01 APPLICABILITY (Tectum), through which an RPI approved fastener is attached. The owner or designate is responsible for the design and engineering of the roof deck and the compatibility of ... Read More
TTEECCHHNNIICCAALL AADDVVIISSOORRYY BBUULLLLEETTIINN
When properly installed using the fasteners and construction design recommended by the deck Tectum E and Tectum NS (Tectum, Inc.) Huber Zip Deck System – A waterproof underlayment such as StormGuard SIP panel manufacturers recommendations for use as a shingle roof deck: ... Fetch Doc
ROOFING SYSTEMS - Best Materials
ROOFING SYSTEMS I NTRODUCTION F LEECE Tectum Deck or Structural Concrete or Steel Deck Insulated Assemblies 1. FleeceBACK-AFX or AFX Pl us 2. ColdApplied Adhesiv e 3. HP Polyiso Insulation Roof Deck 1 2 4 3 1. FleeceBACK-AFX or AFX Pl us 2. ColdApplied Adhesiv e 3. Asphalt Pr imer or ... Read Document
Construction No. 451 - MBCI
Construction No. 451 Metal Roof Deck Panels* 24 MSG minimum coated steel. Maximum panel width 16 in., and rib height 2 in. Panels continuous over two or more spans. Endlaps to occur with panels Fasteners used to attach Tectum deck (Item 4) to structural support (Item 7) to be minimum 6 ... Get Content Here
TOOL REVIEW: ThruLOK Deck Fastener - YouTube
The Fastest, esaiest way to fasten deck framing. What if you could have the same performance as half inch through bolt but with no drilling necessary? This is the ThruLOK, and in this video I'm ... View Video
Roof Deck Erection Manual
TECTUM roof deck products provide a combination of physical characteristics For moving TECTUM roof deck panels across a low slope roof, the use of light roller conveyors (roller skate type) is recommended. fasteners and a slide hammer to drive the ... Visit Document
Bill Khourie's Tectum roof deck Presentation - YouTube
Tectum Inc Roof Deck Presentation by representative Bill Khourie 2013. ... View Video
STANDING SEAM METAL ROOF INSTALLATION - YouTube
This metal roof is a 16" aluminum standing seam - .032" thickness, Snap-Lock profile installed over new plywood deck and GAF Deck Armor breathable synthetic underlayment. ... View Video
FOAMULAR , Thermal, New Roof, Below Membrane
G. [Composite (Tectum, etc.)]: Install deck and secure in accordance with deck manufacturer's recommendations. The deck must be properly secured with all mechanical fasteners flush with the surface ... Return Doc
DURO-LAST DURO-ROOF SYSTEM - Kelly Roofing
DURO-LAST DURO-ROOF Last Roofing, Inc. The following table summarizes the appropriate fasteners to use for different deck types. If Fiber (Tectum) Auger Fastener* Liquid Auger Fastener** ** Liquid Auger must penetrate a minimum of ... Retrieve Full Source
BUR UR Installation Manual B - Tremcoroofing.com
Installation Manual. B U R Tremco A vapor retarder assembly is typically applied on the top of a low slope roof deck. The best design practice is to avoid the use of fasteners through the vapor barrier, as any breach of the vapor retarder may allow air/vapor ... Retrieve Doc
City Of Lynchburg
Install Modified Base Sheet as initial layer directly over existing tectum roof deck. ADD Paragraph 2.12 BASE SHEET FASTENERS A. Basis-of-Design: Carlisle Dual Prong Base Sheet Fasteners. The Carlisle Dual Prong Base Sheet Fastener is designed to secure base sheets over gypsum, fibrous cement and lightweight concrete decks. ... Retrieve Content
Fastener Loads for Plywood – Screws Adjustments for shorter or longer duration of load apply to design values for mechanical fasteners where the strength of the wood (i.e., not the strength of the metal fastener) determines the load capacity. Adjustments of design values for varying ... Doc Retrieval
2015 Roofing Policy - Dgs.maryland.gov
Gypsum, and Tectum) Rosin-sized sheathing paper, 75 lb. 75 lb. ventilated base sheet, mechanical fasteners dictated by deck deck and the roof ply shall be compatible with the roof ply material and asphalt bitumen binder or other adhesive used in the roofing system. ... Get Document
Gypsum Roof Deck Replacement Procedures
Structural engineer must review and approve of any modifications to an existing gypsum roof deck system. gypsum with fasteners designed for this application. Contact fastener suppliers listed in the NRDCA Web Site at www.nrdca.org for further information. ... Document Retrieval
Construction No. 508A TGKX.508A Roof Deck Constructions ...
Roof Deck Fasteners* (Panel Clips) — One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. No. 18 MSG min thick coated steel. Clips spaced 36 in. OC max for steel panels and 18 in. OC max for aluminum panels. ... View This Document
PULL TESTERS FOR FASTENER MEMBRANE FOAM TESTING - Com-Ten
Following fasteners: - Plastic fasteners - Use with tectum and gypsum type fasteners. Also can be used with larger diameter fasteners with no changes or extra pieces. - Steel fasteners - Use with screws, toggle bolts, concrete (threaded or drive-in) type fasteners. Com-Ten's ROOFIRST pull tester is a valuable solution to test fasteners on the roof. ... Get Content Here
Woodblocking - CertainTeed
Woodblocking attached to 18 to 22 ga. steel roof deck can be carried out using #14 or #15 diameter threaded fasteners. These fasteners have an average withdrawal 460 lbf from 33 KSI, 22 gauge steel decking. The industry accepted margin of safety is 1.5:1 with a pull-over value of not less than 125%. ... Access Content
Low Slope Fastening Solutions Guide Featuring Products & Systems
Low Slope Fastening Solutions Guide Featuring Products & Systems Distributed by: BEST MATERIALS ® Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 For insulation attachment to wood and steel roof decks Fasteners Application #12 Dekfast Fasteners Available pre-assembled and loose for ... Retrieve Document